Guide · Choose
Fire safety for mosque carpets: Cfl-s1 explained simply
Cfl-s1, Bfl-s1, B1: what the fire classes mean, who sets the requirement for your building and which documents should come with a carpet.
Cfl-s1 is a European fire class for floor coverings. It often appears in quotes for mosque carpets. What counts, however, is not the short code in the quote, but the classification report for exactly this carpet in exactly this installation.
The fire classes under EN 13501-1 explained simply
The European standard EN 13501-1 classifies building products by their reaction to fire. Floor coverings have their own classes, recognisable by the suffix ‘fl’ (for ‘floorings’). The smoke class follows after it.
| Class | What it means in practice |
|---|---|
| A1fl, A2fl | The highest classes for floor coverings. |
| Bfl | Better performance than Cfl. |
| Cfl | Often stated for carpets. Whether Cfl is enough depends on the requirement for your building. |
| Dfl | Lower performance than Cfl. |
| Efl | Lower performance than Dfl. |
| Ffl | No performance determined. |
The smoke class s1 stands for low, s2 for limited smoke production. A carpet classified ‘Cfl-s2’ is therefore not the same as ‘Cfl-s1’. If your requirement names a smoke class, the carpet must meet it in full.
How is it tested?
For floor coverings, two tests are common. In the small-flame test (EN ISO 11925-2), a small flame is applied to check whether it spreads across the sample. In the radiant panel test (EN ISO 9239-1), the sample lies horizontally under an inclined radiant heater. Flame spread and smoke production are measured.
Cfl-s1 and B1: what is the difference?
B1 is an older German building material class from DIN 4102-1 and still appears on some data sheets. Cfl-s1 and Bfl-s1 come from the European standard. The two systems are not directly convertible into each other.
Within the EU, carpet as a floor covering usually falls under the European product standard EN 14041. It covers textile floor coverings, but explicitly not loose-laid mats, runners and rugs. If a product falls under a harmonised standard, the manufacturer must draw up a declaration of performance and affix the CE marking. Reaction to fire is one of the characteristics stated there.
It follows that a ‘B1 certificate’ alone is not the proof you should expect for a carpet covered by the European standard. Ask for the European class. Whether your authority accepts other evidence in an individual case is for that authority to decide. Outside the EU, ask which classification and documents your country requires.
Which requirements apply to your mosque?
There is no universal answer. What applies is set by the building and fire safety rules in your country or region, your building approval and, where there is one, the fire strategy or fire safety concept for your building. In Germany, for example, the rules differ from one federal state to another. This is not legal advice.
A few points help you find your way:
- The requirement for a floor covering can differ from one area of the building to another. Clarify the prayer hall, corridors, entrance, stairs and gallery separately.
- A large prayer hall in which many people gather may be subject to stricter requirements than a small prayer room. Your authority or fire safety adviser can tell you whether this is the case for your building.
- Other rooms in the same building, such as a large function hall or a foyer, may be subject to different rules than the prayer hall.
Whether and which requirement applies to your building is shown in your building approval or fire strategy, or can be confirmed by the authority that issued them.
So ask in writing – your local authority, building control, the fire authority or your fire safety adviser. Useful questions are:
- Which fire class is required for the floor covering in the prayer hall?
- Does the same requirement apply to the corridor, entrance, stairs, gallery and women’s area?
- Is there a fire strategy, and what does it say about the floor covering?
- Are there conditions for the installation, for example regarding the underlay?
These answers belong in your enquiry to the supplier. That way you can compare quotes on the same basis.
Which documents to ask for
A short code in a quote is no substitute for proof. The test report records the measured results of a testing body. The classification report assigns these results to a class and describes the product and the use it applies to. Ask for these documents:
- Declaration of performance from the manufacturer, if the carpet falls under EN 14041.
- Classification report under EN 13501-1 from a testing body, together with the test report it is based on.
- Product name and construction in the report that match the quote (material, backing, thickness).
- Tested installation method: subfloor, adhesive or installation without adhesive, underlay.
- Date, issuer and, if stated, period of validity.
- The complete class including the smoke class, i.e. ‘Cfl-s1’ and not just ‘Cfl’.
Why the installation method matters: during the test, the sample is placed on a substrate that represents the later floor build-up and fixed as it would be in practice. Example reports for floor coverings state precisely on which substrates the class applies, and some exclude additional insulation or moisture underlays. So only plan with an underlay that appears in the report.
Finally, check the link: does this report really belong to this carpet and this installation? Further points to check are in the mosque carpet buying checklist and in our guide How to recognise a good mosque carpet: technical data.
Warning signs
Ask questions before ordering if you see the following:
- ‘Non-combustible’ as a description of a carpet. That is a far-reaching claim, which would need its own classification. If a carpet is described this way, ask for the report that shows it.
- A certificate only for the yarn or the fibre. The class applies to the finished floor covering in the tested build-up.
- Documents for a different product. Name, construction or backing differ from the quote.
- No information on the installation method. Then it is unclear whether the class applies to your installation.
- Only ‘B1’ without a European class. Ask for the classification under EN 13501-1.
- Only marketing claims such as ‘flame-retardant’ without a class and a report.
The class refers to the carpet’s entire tested build-up, not just the fibre. For an overview of the fibres and their properties, see our mosque carpet materials compared.
How mosque-carpet.com handles fire safety information
We only state a fire class together with the test report for that carpet.


